Guide · Riding, swimming and rowing

FTP Explained: Cycling Power Zones from One Test

One test gives you the number every zone hangs on. How to run it and what to do in each zone.

4 min read

Why you need an FTP

Your power meter shows watts all day long, but a number on its own doesn’t tell you whether 220 W is an easy spin or a suffer-fest. For that you need a yardstick that belongs to you. Functional threshold power (FTP) is that yardstick: the highest steady output you can maintain for roughly an hour.

It sits close to your lactate threshold, the point where lactate starts piling up faster than your body can clear it. Stay under FTP and you can keep going for ages. Go over, and the clock starts ticking. At 105% of FTP you might last 20 to 30 minutes; at 120%, a few.

Testing it

An all-out hour is miserable and almost impossible to pace, so most riders use something shorter.

The 20-minute test. Warm up with 20 easy minutes, a few brief fast spins and one hard five-minute effort, so the freshness is gone but the legs aren’t. Then give 20 minutes everything you’ve got, paced evenly.

FTP ≈ 0.95 × average power of the 20-minute effort

The ramp test. Every minute the target rises by a set step, and you carry on until you can’t. Take 75% of the best one-minute average as FTP. It’s quicker and needs no pacing, but it rewards riders with a big anaerobic engine and shortchanges the steady, diesel types.

Your ride history. Analysis software can estimate it from your best efforts at many durations. A recent 40 km time trial average is also a close match.

Every method is an estimate. Researchers who set them against lab thresholds see decent agreement for groups, yet a rider’s own result can be off by several percent. Treat your FTP as good to about ±5 W, and nudge it if training says otherwise.

The seven zones

The scheme most riders use comes from Andrew Coggan and cuts the range into seven zones, each a percentage of FTP.

Zone Name % of FTP Typical duration you can hold it
1 Active recovery under 55% All day
2 Endurance 56–75% Several hours
3 Tempo 76–90% 1 to 3 hours
4 Threshold 91–105% 20 to 60 minutes
5 VO2 max 106–120% 3 to 8 minutes
6 Anaerobic capacity 121–150% 30 seconds to 2 minutes
7 Neuromuscular power maximal Under 15 seconds

A worked example

Imagine a rider whose 20-minute test averaged 263 W.

FTP = 0.95 × 263 = 249.9, so call it 250 W. At 70 kg that’s 3.57 W/kg.

Zone Range in watts
1 Active recovery below 138
2 Endurance 140–188
3 Tempo 190–225
4 Threshold 228–263
5 VO2 max 265–300
6 Anaerobic capacity 303–375
7 Neuromuscular sprint

What would that rider do with the zones? A threshold session might be 2 × 20 minutes at 235 to 250 W, with five easy minutes between. A VO2 max day could be 5 × 4 minutes at 275 to 290 W, recovering four minutes each time. Endurance rides stay at 140–188 W for two hours or more.

What each zone does for you

Zones 1 and 2 lay the aerobic foundation: more capillaries, more mitochondria, and a better ability to burn fat. Spend the bulk of your hours here.

Zone 3 feels like a brisk group ride: hard, but sustainable. It’s productive and tiring in equal measure, and too much of it leaves you flat for the sessions that matter.

Zone 4 is what lifts FTP itself, usually through intervals of 8 to 30 minutes.

Zone 5 pushes up your ceiling for aerobic power, using intervals of three to eight minutes.

Zone 6 trains you to fire off short, brutal efforts again and again, as in a criterium or on a steep little climb.

Zone 7 is straight sprinting. Nerves and muscle set the limit, not fuel, so average power is meaningless. Look at peak power.

Should you train by watts or beats?

Watts tell you what you’re producing right now. Heart rate tells you what it’s costing, a minute or more behind, and it moves with heat, fatigue and caffeine. Use power for intervals and heart rate as a second opinion. When your heart rate at a fixed power falls across a few weeks, fitness is improving; when it’s high on one particular day, think tiredness, heat or a bug on the way.

Average power versus normalised power

On a stop-start ride, plain average power sells the effort short, because every surge costs more than the coasting gives back. Normalised power fixes that by weighting hard efforts more heavily; it approximates the constant output that would have taxed you equally. Divide it by FTP to get the intensity factor, where 1.0 over an hour means, by definition, you emptied the tank.

Mistakes to avoid

  • Starting the test too fast. Keep the opening five minutes under control. A second-half fade gives you a number that’s too low.
  • Clinging to a stale figure. After time off, FTP falls, and zones based on last season will be too hard.
  • Seeing zone edges as walls. 189 W and 191 W are the same effort. The bands show what a ride is for; they aren’t switches.
  • Mixing power meters. Units can disagree by a few percent. Track your progress on a single device.

These are training measures only, not medical advice.

Questions people ask

What does FTP stand for in cycling?
It means functional threshold power: the top average output, in watts, that you could sustain for around an hour before having to back off. Your power zones are all measured against it.
What's the best way to test FTP?
The usual field test is 20 minutes flat out, preceded by a warm-up with one hard five-minute effort. Multiply that 20-minute average by 0.95. If you prefer a ramp test (power rises each minute until you stop), take 75% of the best minute.
Which seven zones do power-based plans use?
Each is a slice of FTP. Active recovery (zone 1) is under 55%, endurance 56–75%, tempo 76–90%, threshold 91–105%, VO2 max 106–120%, anaerobic capacity (zone 6) 121–150%, and zone 7 is neuromuscular power: all-out sprints.
When should I redo my FTP test?
A gap of six to eight weeks during a block is common. Go sooner if workouts set from the old figure feel clearly too soft or too brutal, and repeat the same protocol on the same bike or trainer in similar conditions.
Will my FTP be the same on a trainer and on the road?
Often it won't. Plenty of riders produce 3% to 8% less on an indoor trainer, mostly down to heat and a locked riding position. If you ride both, test both.

Where the numbers come from

  1. Allen H, Coggan AR, McGregor S. Training and Racing with a Power Meter, 3rd edition. VeloPress, 2019
  2. Borszcz FK, Tramontin AF, Bossi AH, Carminatti LJ, Costa VP. Functional threshold power in cyclists: validity of the concept and physiological responses. International Journal of Sports Medicine 39(10), 2018
  3. MacInnis MJ, Thomas ACQ, Phillips SM. The reliability of 4-minute and 20-minute time trials and their relationships to functional threshold power in trained cyclists. International Journal of Sports Physiology and Performance, 2019